五个厂家氯雷他定片或胶囊体外溶出度比较 |
投稿时间:2007-11-01 点此下载全文 |
引用本文:李蓉,李明,葛文俊.五个厂家氯雷他定片或胶囊体外溶出度比较[J].药学实践杂志,2008,(5):350~352 |
摘要点击次数: 2188 |
全文下载次数: 381 |
|
|
中文摘要:目的:比较5个厂家的氯雷他定片剂或胶囊剂的溶出度,为临床用药提供参考。方法:采用转篮法进行体外溶出度实验,以紫外分光光度法进行含量测定,计算其累积溶出百分率,并以威布尔方程拟合溶出参数,用方差分析对组间溶出参数进行统计学处理,采用Q检验进行两两检验。结果:5个厂家的氯雷他定片或胶囊的体外溶出度均符合2005年版国家药典标准的规定,但各厂家氯雷他定片或胶囊的溶出度参数m、Kr、T50、T30、Td、T80间存在显著性差异(P<0.05)。结论:不同厂家氯雷他定片或胶囊的溶出参数存在差异,临床用药时应加以注意。 |
中文关键词:氯雷他定 溶出度 紫外分光光度法 |
|
Comparison of dissolution of loratadine tablets or capsules in vitro from five manufacturers |
|
|
Abstract:Objective:To compare the dissolution of loratadine tablets or capsules in vitro from five different pharmaceutical facto- ries and give suggestions for clinical use.Methods:The dissolution tests were carried out with rotating basket and the content of lorata- dine was determined by UV spectrophotometry.The accumulation dissolution percent was calculated and Weibull formula was used to fit the deta.The dissolution parameters was statistically analyzed by variance analysis and Q test.Results:The dissolution of loratadine tablets or capsules in vitro from five factories were all in conformity with Chinese Pharmacopoeia(2005 edition).But significant differ- ences of dissolution parameters m,Kr,T30,T50,Td and T80 were found among the loratadine tablets or capsules from five factories(P<0.05).Conclusion:There is a significant difference in dissolution parameters of the loratadine tablets or capsules from five factories, indicating that attention should be paid to their difference in clinical use. |
keywords:loratadine dissolution UV spectrophotometry |
查看全文 查看/发表评论 下载PDF阅读器 |
|
关闭 |
|
|
|