旋光法测定注射用苯唑西林钠的含量 |
投稿时间:2004-02-10 点此下载全文 |
引用本文:王晓玲,李玉兰.旋光法测定注射用苯唑西林钠的含量[J].药学实践杂志,2004,(5):298~298,312 |
摘要点击次数: 1046 |
全文下载次数: 914 |
|
|
中文摘要:目的 建立旋光法测定注射用苯唑西林钠含量的方法。方法 以水为溶剂,运用旋光法对注射用苯唑西林钠进行含量测定。结果 苯唑西林钠浓度在1~10mg/mL范围内与其旋光度呈良好线性关系,回归方程:C=0.391314+5.26150a,r=0.9997,平均回收率102.1%,RSD为1.83%。结论 本法简便易行,结果准确,可作为该原料的质控方法。 |
中文关键词:旋光法 注射用苯唑西林钠 含量测定 |
|
Determination of the content of oxacillin sodium for injection by polarimetry |
|
|
Abstract:Objective To establish an accurate method for determination of the content of oxacillin sodium for injection. Methods Oxacillin sodium for injection was determinted with as water by polarimetry. Results The standard curve was linear in the range of 1~10 mg/mL. The regression equation was: C = 0.391 314 + 5.261 50a,r = 0.9997. The average recovery rate was 102.1%,RSD |
keywords:polarimetry oxacillin sodium injection determination |
查看全文 查看/发表评论 下载PDF阅读器 |
|