紫外分光光度法测定复方薄荷脑滴鼻液中樟脑的含量
投稿时间:2003-09-15    点此下载全文
引用本文:顾伟鹰,张和平,黄伟芬.紫外分光光度法测定复方薄荷脑滴鼻液中樟脑的含量[J].药学实践杂志,2004,(3):164~165
摘要点击次数: 1228
全文下载次数: 1732
作者单位
顾伟鹰 上海市第七人民医院, 上海 200137 
张和平 上海市第七人民医院, 上海 200137 
黄伟芬 上海市第七人民医院, 上海 200137 
中文摘要:目的 建立复方薄荷脑滴鼻液中樟脑的含量测定方法。方法 采用紫外分光光度法,于(292±1)nm波长处直接测定樟脑的含量。结果 在1.62~3.24mg/mL的浓度范围内,线性关系良好,相关系数r=0.9992,平均回收率100.06%,RSD为1.29%。结论 方法简便、快速、准确。
中文关键词:紫外分光光度法  复方薄荷脑滴鼻液  樟脑  含量测定
 
Determination of camphor in compound menthol nasal drops by ultraviolet spectrophotometry
Abstract:Objective To establish a quantitative analysis method for camphor in compound menthol nasal drops.Methods The camphor was determined directly at (292±1)nm by ultraviolet spectrophotometry.Results:The calibration curve was linear in the range from 1.62~3.24mg/mL with r=0.9992,the average recovery and relative standard deviation were 100.06% and 1.29% respectively. Conclusion The method is simple,rapid and accurate.
keywords:ultraviolet spectrophotometry  compound menthol nasal drops  camphor  determination of content