不同密度滚轮微针对曲安奈德的透皮促渗作用
投稿时间:2013-03-22  修订日期:2013-05-14  点此下载全文
引用本文:张娟娟,朱全刚,张立超.不同密度滚轮微针对曲安奈德的透皮促渗作用[J].药学实践杂志,2013,31(6):415~417,461
摘要点击次数: 1266
全文下载次数: 269
作者单位E-mail
张娟娟 宁夏医科大学研究生院, 宁夏 银川 750004
上海市第七人民医院药学部, 上海 200137 
 
朱全刚 第二军医大学附属长海医院药学部, 上海 200433  
张立超 上海市第七人民医院药学部, 上海 200137 lingli_Z163@163.com 
基金项目:浦东新区科委基金资助(PKJ2009-Y33).
中文摘要:目的 探讨不同密度滚轮微针对曲安奈德经皮渗透的影响。方法 采用改良Franz扩散池法考察体外经皮渗透特性,以离体裸鼠皮肤为屏障,对照组、192针、540针滚轮微针处理组分别于2、4、6、8、10、12 h取接收液0.2 ml,用HPLC法测定曲安奈德含量,计算累积渗透量,并测定皮肤内曲安奈德滞留量。采用测定血药浓度法考察在体吸收特性,在体给药2h后HPLC法测定各组皮肤及血浆中曲安奈德的含量。结果 两种密度滚轮微针对曲安奈德均有不同程度的促透作用。离体透皮实验结果显示,192针微针处理组和540针微针处理组的累积渗透量Q分别是对照组的1.3倍和2.2倍,相应的皮肤内滞留量也分别是对照组的1.9倍和2.8倍。在体实验结果显示,192针微针和540针微针组的皮肤滞留量是对照组的2.1和2.3倍,同时也将血药浓度提高了1.3倍和1.4倍。结论 两种不同密度滚轮微针均能有效提高曲安奈德的经皮渗透量,提高皮肤内药物含量,同时也导致血药浓度的增加,且不同密度微针的促透作用有所不同。
中文关键词:滚轮微针  曲安奈德  经皮渗透
 
Effect of different density microneedle-roller on transdermal delivery of triamcinolone acetonide
Abstract:Objective To study the effects of different density microneedle-roller arrays on transdermal delivery of triamcinolone acetonide. Methods The in vitro permeation characteristics through isolated nude mouse skin were studied by modified Franz diffusion cells. Levels in the receptor solution of the control group, the 192 needles microneedle rooler group and the 540 needles microneedle rooler group were measured by HPLC at 2、4、6、8、10 and 12 h, and sampling volume was 0.2 ml. The accumulative penetration amount were counted and the level of triamcinolone acetonide in skin were determined. Plasma concentrations of triamcinolone acetonide and skin volume were measured 2 hours later after administration by HPLC to observe the penetration of triamcinolone acetonide in vivo. Results Different density microneedle-roller could promote the transdermal delivery of triamcinolone acetonide respectively. Transdermal experiment results showed that the cumulative infiltration volume of 192 needles group was about 1.3 times of the control samples, and 540 needles was 2.2 times. Accordingly, skin retention volume were1.9times and 2.8 times of the control group respectively. In vivo results showed that skin retention volume were 2.1 times and 2.3 times of control group, while triamcinolone acetonide in plasma were 1.3 times and 1.4 times of control group. Conclusion Microneedles could effectively promote the skin permeability and deposition of triamcinolone acetonide, and triamcinolone acetonide in plasma was increased at the same time. The promoting of different density was diverse.
keywords:microneedle-roller  triamcinolone acetonide  percutaneous penetration
查看全文  查看/发表评论  下载PDF阅读器
关闭

分享按钮